Products · Voice Alarm & Evacuation

Voice Alarm & Evacuation

Zoned evacuation controllers and terminals built on an EN 54-style architecture, with line and battery supervision for campus, metro and industrial projects.

EASTVO manufactures 8 models in this range. Specifications below are the ones specified most often on tenders; full data sheets are available per model. For a project point schedule, send a floor plan to [email protected].

· 8 models

EN-1003 Remote Paging Microphone — EASTVO Voice Alarm & Evacuation
EN-1003 Remote Paging Microphone
Remote Paging Microphone, 12 zone and expandable to 120 zones by connection with zone keypad, DC24V power supply
View specifications →
EN-1004 Fireman Microphone — EASTVO Voice Alarm & Evacuation
EN-1004 Fireman Microphone
Fireman Microphone, built-in EVAC/Alert message, program button setting, capacity is of 120 zones, DC24V power supply, with door and lock.
View specifications →
EN-1005 Remote Paging Microphone — EASTVO Voice Alarm & Evacuation
EN-1005 Remote Paging Microphone
Remote Paging Microphone, touch screen type, 120 zones capacity, each system can connection up to 32 remote microphone, DC24V power supply
View specifications →
EN-12FQ 12 Zone Keypad — EASTVO Voice Alarm & Evacuation
EN-12FQ 12 Zone Keypad
12 Zone Keypad for remote microphone EVAC-5500TM, system capacity up to 120 zones.
View specifications →
EN-240F6 6 Zone Router — EASTVO Voice Alarm & Evacuation
EN-240F6 6 Zone Router
6 Zone Router, built-in 240W class-D amplifier, with 6 zone speaker outputs and volume control, receive sources and fire alarm message from master controller, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation.
View specifications →
EN-240K6 6 Zone EVAC Controller — EASTVO Voice Alarm & Evacuation
EN-240K6 6 Zone EVAC Controller
6 Zone EVAC Controller, built-in 240W class-D amplifier, built-in EVAC and alert voice message by SD card, with fireman microphone, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation.
View specifications →
EN-500F6 6 Zone Router — EASTVO Voice Alarm & Evacuation
EN-500F6 6 Zone Router
6 Zone Router, built-in 500W class-D amplifier, with 6 zone speaker outputs and volume control, receive sources and fire alarm message from master controller, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation.
View specifications →
EN-500K6 6 Zone EVAC Controller — EASTVO Voice Alarm & Evacuation
EN-500K6 6 Zone EVAC Controller
6 Zone EVAC Controller, built-in 500W class-D amplifier, built-in EVAC and alert voice message by SD card, with fireman microphone, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation.
View specifications →

Voice Alarm & Evacuation — questions buyers ask

What does the voice alarm range include?

Zoned evacuation controllers and terminals, with supervision of speaker lines and standby batteries, built on an EN 54-style architecture for campus, metro and industrial projects. The controller is the part that decides which zones hear an evacuation message.

Is the system EN 54 certified?

The range is built on an EN 54-style architecture with speaker-line and battery supervision. Certification status is project-specific, so ask [email protected] for the current certificate set before writing a standard into a tender — that avoids a compliance gap at handover.

What happens when the fire panel trips?

The controller takes the alarm contact, overrides background music and scheduled audio, and plays the evacuation message to the zones mapped to that alarm. Zones outside the alarm stay on normal duty, which matters in a large building where a full-site evacuation is not the right response.

What is supervised?

Speaker lines and standby batteries. An open or shorted line and a failed battery are reported before an incident rather than during one — that is the whole point of supervision, and it is what a fire authority checks during acceptance.

Can one system handle both daily paging and evacuation?

Yes. Daily paging and evacuation share the same 100V line and the same speaker set, and the controller gives the alarm input priority over scheduled and live audio. One set of loudspeakers, two duties.